Relief Valve
Miter Cut
Flip Top
Finishing Cone
Cone Rain Cap
Rain Cap - Model 2
Rain Cap - Model 1
Storm Collar
Adjustable Flashing
Flashing
Roof Brace
No Loss Cap
Wall Thimble
Roof/Floor Penetration Shield
Guy Wire
Floor Guide
Wall Guide
Suspension Band
Half Angle Ring
Cradle Support
Wall Support
Length Anchor Plate
Anchor Plate - Ventilated
Anchor Plate - Heavy Duty
Anchor Plate
CIX/CAX to CT Adaptor
CT to CIX/CAX Adaptor
Square to Round Adaptor
Fan Adaptor
Viessmann Vitorond Adaptor
Cleaverbrooks Flex Adaptor
Flanged Adaptor - Female
Flanged Adaptor - Male
Single Wall Adaptor - Female
Single Wall Adaptor - Male
ANSI Flange Adapter - Female
ANSI Flange Adapter - Male
Stepped Increaser
Tapered Increaser
Damper Length
Locking Band
No Tool Access Door
Drain Tee Cap
Tee Cap
Grease Tees (CIX only)
90° Grease Tees (CIX only)
45° Tee Y
45° Tee Relief Valve
Double 45° Tee, Smaller Snout
45° Tees
90° Tees
45° Elbows
15° Elbows
3° Elbow Kits
Nozzle Lengths
Horizontal Drain Lengths
Drain Lengths
Bellows Lengths
Variable Lengths
Adjustable Lengths
Lengths
-
Relief Valve
Helps control the venting pressure should a backfire occur. Must be used in conjunction with ANSI flanged adapter and 45° tee relief valve. Use on engine exhaust. -
Miter Cut
Use for horizontal engine exhaust termination. -
Flip Top
Use to prevent moisture and debris from entering system. Flip top opens with internal pressure and closes when no pressure is present. For engine exhaust application. -
Finishing Cone
Use to provide the greatest draft. Requires a drain at bottom of stack. -
Cone Rain Cap
Use to provide the greatest degree of rain protection. Available with bird screen. -
Rain Cap - Model 2
Use to provide the greatest degree of rain protection. Model 2 is available with bird screen. -
Rain Cap - Model 1
Use to provide the greatest degree of rain protection. Model 2 is available with bird screen. -
Storm Collar
Use above the flashing for complete weatherization above the roof. To be sealed with outer joint sealant (not included). -
Adjustable Flashing
Use in conjunction with storm collar for weatherization at the roof. 5° to 30° pitch. -
Flashing
Use in conjunction with storm collar for weatherization at the roof. Storm collar included. -
Roof Brace
Use for bracing in vertical installation above the roof. All hardware included except brace and connection to roof. -
Wall Thimble
Use where chimney passes through a combustible wall. Maintains a minimum of 2” clearance to the opening on CIX installations and 4” clearance to the opening on CAX. Not listed for diameter larger than 10”. -
Roof/Floor Penetration Shield
Use where chimney passes through a combustible roof or structure. Maintains a minimum of 2” clearance to the opening on CIX installations and 4” clearance to the opening on CAX. -
Guy Wire
Use for guiding in vertical installation above the roof. All hardware included except wire, tensioner and connection to roof. See instruction manual for required specifications. -
Floor Guide
Use for guiding in vertical installation when passing through a floor or roof. Maintains a minimum of 2” clearance to the opening on CIX installations and 4” clearance to the opening on CAX. All hardware included except connection to structure. -
Wall Guide
Use for guiding vertical installation attached to the wall. Maintains a minimum of 1” clearance to the wall on CIX and 4” on CAX. Extension for additional clearance of 3½” is included. All hardware included except connection to structure. Flexible strap (not included) can be used to add rigidity when using extension-see instruction manual for required specifications. -
Suspension Band
Use for supporting and guiding the stack in horizontal runs. Allows 4” of travel for thermal expansion. Rail, trolley and band included. Flexible support strap (not included) is used to join the band and the trolley-see instruction manual for required specifications. All hardware included except connection to structure. -
Half Angle Ring
Use for supporting and guiding the stack in horizontal runs. Not recommended for thermal expansion systems. See installation instructions for spacing. -
Cradle Support
Use for supporting and guiding the stack in horizontal runs. Not recommended for thermal expansion systems. See installation instructions for spacing. -
Wall Support
Use for supporting the stack in vertical runs in contact with combustible materials and to provide a fixed point for thermal expansion consideration. Maintains a minimum of 2½” clearance to the wall on CIX and 4½” on CAX, and up to 7½” on CIX and 9½” on CAX when wall brace is extended. All hardware included except connection at wall. -
Length Anchor Plate
Composed of a straight section with an effective length of 3¾” for CIX, integrated into a support plate. The Length Anchor Plate doesn’t need any clamp flange (and its hardware) for its installation, so it is easier and faster to install. The APL must be attached to the building structure or support with rigid non-combustible structural members. -
Anchor Plate - Ventilated
Use for supporting the stack in vertical runs in contact with combustible materials and to provide a fixed point for thermal expansion consideration. Maintains a minimum of 2” clearance to the opening on CIX and 4½” on CAX. All hardware included except connection to structure. -
Anchor Plate - Heavy Duty
Use for supporting the stack in vertical or horizontal runs and to provide a fixed point for thermal expansion consideration. Heavy-duty steel “C” channel base - 2 ½” x 1 ½”. -
Anchor Plate
Use for supporting the stack in vertical or horizontal runs and to provide a fixed point for thermal expansion consideration. Maintains a minimum of 1” clearance to the opening on CIX installations and 4” clearance to the opening on CAX. All hardware included except connection to structure. Must not be in contact with combustible. -
CIX/CAX to CT Adaptor
Use to connect CIX or CAX model chimney to CT chimney liner. Locking band included. -
CT to CIX/CAX Adaptor
Use to connect CT model chimney liner to CIX or CAX. Locking band included. -
Square to Round Adaptor
Connects to kitchen hood. Locking band included. Made to order. -
Fan Adaptor
Use for connection to an “up-blast” kitchen fan. -
Viessmann Vitorond Adaptor
Use as single wall starter piece for Vitorond VD2 and VD2A Viessmann appliances. -
Cleaverbrooks Flex Adaptor
Use as starter piece for Flexible Watertube FLX Cleaver Brooks appliance. -
Flanged Adaptor - Female
Use on standard appliances such as kitchen hood exhausts. Flanged at the end. Locking band included. -
Flanged Adaptor - Male
Use on standard appliances such as kitchen hood exhausts. Flanged at the end. Locking band included. -
Single Wall Adaptor - Female
Use as a non-welded attachment for appliances having an unflanged outlet. Locking band included. -
Single Wall Adaptor - Male
Use as a non-welded attachment for appliances having an unflanged outlet. Locking band included. -
ANSI Flange Adapter - Female
Use for connecting a 125 or 150 lb. ANSI flange. 1/4” thickness with a bolt hole pattern, bolt hole center pattern and quantity per 125-lb ANSI. Locking band included. -
ANSI Flange Adapter - Male
Use for connecting a 125 or 150 lb. ANSI flange. 1/4” thickness with a bolt hole pattern, bolt hole center pattern and quantity per 125-lb ANSI. Locking band included. -
Stepped Increaser
Use when a pipe diameter change is required in a small space. More restrictive than the tapered increaser. Locking band included. -
Tapered Increaser
Use when a pipe diameter change is required. Locking band included. -
Locking Band
Use to clamp and seal parts together. To be sealed with outer joint sealant (not included). Included with components that require the locking band. -
No Tool Access Door
Use for inspection and cleaning. Greaseproof and fire-tight seal. Replacement gaskets available. -
Drain Tee Cap
Use to close and seal unused tee ports and to provide drain point for rain or condensation. Locking band included. -
Tee Cap
Use to close and seal unused tee ports. Locking band included. -
Grease Tees (CIX only)
Use to provide low-pressure drop for joining appliances. Offers same diameter on all branches. Available with smaller snout. Locking band included. Locking band included. -
90° Grease Tees (CIX only)
Use in grease duct applications as a horizontal-to-vertical connection with an inspection or clean-out access. Locking band included. Dam can be ordered in #1, 2 or 3 position. -
45° Tee Y
Use to provide low-pressure drop for joining appliances. Offers same diameter on all branches. Available with smaller snout. Locking band included. -
45° Tee Relief Valve
Use to combine with the relief valve and female ANSI flange adapter. Locking band included. Same dimensions as 45° Tee. Locking band included. -
Double 45° Tee, Smaller Snout
Used to change direction at 45° breeching or inspection access. -
45° Tees
Use to change direction at 45° breeching or inspection access. -
90° Tees
Use to change direction at 90° breeching or inspection access. Use as an inspection access in horizontal runs for grease duct applications (CIX only). Do not use in diesel/turbine applications. Locking band included. -
45° Elbows
Use to change direction of the stack or to provide offset. -
15° Elbows
Use to change direction of the stack or to provide offset. -
3° Elbow Kits
Use to change direction of the stack or to provide offset. 3° elbows provide a minimum slope for horizontal run. Locking band included. Comes in pairs. Effective Length 17 3/8”. -
Nozzle Lengths
Use to insert a fire-suppression or wash-down nozzle in CIX grease duct applications. Use as a test port in CAX applications. Locking band included. -
Horizontal Drain Lengths
Use as a horizontal drain in grease duct applications. Locking band included. -
Drain Lengths
Use to drain rainwater or condensation from inner wall. Locking band included. -
Bellows Lengths
Use to compensate for thermal expansion and to minimize vibration. For diameters larger than 24" the part will require special ordering and additional lead time will apply. Has a 3” maximum compression. Locking band and liner included. -
Variable Lengths
Used to adjust to fit odd dimensions. Not used for thermal expansion. Can be used in positive pressure applications. Locking band included. -
Adjustable Lengths
Used to add length. Adjust to fit odd dimensions and compensate for thermal expansion. Not suitable for positive pressure applications. Locking band included. -
Lengths
Available in sizes from 5- to 36-inch diameters, the CIX line offers double-wall, 2-inch insulated chimneys, and the CAX offers a 2-inch air insulated product.