Horizontal Kit
Vertical Kit - Flat Ceiling
Vertical Kit - Flat Ceiling
Fresh Air Intake Kit
Vent Lengths
Adjustable Vent Lengths
Flexible Vent Lengths
Flex Trim Collar
Female Flex Adapter
Male Flex Adapter
Appliance Adapter
Harman Adapter
Harman Adapter Increaser
Appliance Adapter/Increaser
Quick Release Adapter
Increaser
Chimney Adapter
45° Elbow
90° Elbow
Regular Tees
Increaser Tee w/ Clean-Out Tee Cap
Adapter Tee w/ Clean-Out Tee Cap
Increaser Adapter Tee w/ Clean-Out Tee Cap
Double Tee w/ Clean-Out Tee Cap
Wall Thimble
Wall Thimble Air Intake Kit
Ceiling Support Firestop Spacer
Ceiling Support Firestop Spacer - 3
Wall Strap
Adjustable Wall Strap
Wall Strap Extension
Cathedral Ceiling Support Box
Ceiling Support/Wall Thimble Cover
House Shield
Attic Insulation Shield
Adjustable Roof Flashing
Reduction Collar
Tall Cone Roof Flashing
Storm Collar
Vertical Cap
Horizontal Cap
Square Horizontal Cap
Secure Pellet Flex
Prairie Termination Cap
Fresh Air Inlet Increaser
-
Horizontal Kit
Kit includes: Round Horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4” Kit includes a 3”-4” Appliance Adapter/Increaser, painted black.
-
Vertical Kit - Flat Ceiling
Kit includes: Vertical Cap, Storm Collar, Ceiling Support Firestop Spacer, Adjustable Flashing, and Appliance Adapter. Pipe lengths not included. 4” Kit includes a 3”-4” Appliance Adapter/Increaser, painted black. Support Clamp included.
-
Vertical Kit - Flat Ceiling
Kit includes: Vertical Cap, Storm Collar, Cathedral Ceiling Support Box with trim and clamp, Adjustable Flashing, and Appliance Adapter. Pipe lengths not included. 4” Kit includes a 3”-4” Appliance Adapter/Increaser, painted black.
-
Fresh Air Intake Kit
Kit includes: faceplate with screen, moisture barrier, aluminum flex, and two clamps.
Allows fresh air into an existing pellet stove installation that had been using inside air. Allows an installer to decide the best possible location for the air intake vent, not the same location as the wall thimble. The 2” diameter, 18” length flex hose expands to approximately 60”.
-
Vent Lengths
Features fully unitized, twist-lock construction in 3” and 4” diameters. Listed at 1” clearance to combustibles in the USA and Canada. It can be used in both vertical and horizontal installations. Stainless steel laser welded inner wall, combined with a galvalume laser welded outer wall. Pipe OD is diameter plus 5/8”. Galvalume or painted black outer finish. 12” length available with stainless steel outer (SS). To calculate installed length, subtract 1 1/2” from each length of pipe.
-
Adjustable Vent Lengths
Use to add length. 12” pipe adds 3”-10” of length, 18” pipe adds 3”-16” of length, when used with rigid sections of pipe. Galvalume or painted black outer finish.
-
Flexible Vent Lengths
Use for offsetting rigid pipe around smoke shelf in masonry chimney only. Allows for offsets with biofuel appliances. Female and male ends twist-lock. Female end swivels for easy alignment. 60” flex section. Not for use in attic or wall spaces.
-
Flex Trim Collar
Use to connect Secure Pellet rigid pipe to a masonry chimney with stainless steel flexible relining. Female end swivels to allow ease of connection.
-
Female Flex Adapter
Use to connect Secure Pellet to Secure Pellet Flex when relining a masonry chimney. Only approved for use with Secure Pellet Flex.
-
Male Flex Adapter
Use to connect Secure Pellet Flex to Secure Pellet when relining a masonry chimney. Only approved for use with Secure Pellet Flex.
-
Appliance Adapter
Use to attach to appliance outlet allowing for easy pipe connection. Seal adapter to appliance with high temperature sealant.
-
Harman Adapter
Use to provide a secure, tight fit to the exhaust outlet on any Harman Pellet Stove. Seal with high temperature silicone sealant to insure a tight connection.
-
Harman Adapter Increaser
Use to increase vent diameters. Specifically designed for Harman Pellet Stoves.
-
Appliance Adapter/Increaser
Use to attach to appliance outlet allowing for easy pipe connection. Allows connection of 4” vent to 3” appliance outlet. Seal adapter to appliance with high temperature sealant.
-
Quick Release Adapter
Use to attach to appliance outlet allowing for easy pipe connection. Features an adjustable hose clamp and gasket to form a tight seal. The hose clamp can be loosened and tightened as needed to disconnect and connect the vent to the appliance.
-
Increaser
Use to transition from 3” pipe to a 4” pipe. Not a decreaser or stove adapter.
-
Chimney Adapter
Use to transition between Secure Pellet to existing chimney such as Secure Temp ASHT+ or S2100+.
-
45° Elbow
Offsets obstructions as needed. Elbows swivel 360° at base. Angle not adjustable.
-
90° Elbow
Offsets obstructions as needed. Elbows swivel 360° at base. Angle not adjustable.
-
Regular Tees
Use for a 90° offset. Branch swivels for alignment. Removable twist-lock clean-out tee cap included.
-
Increaser Tee w/ Clean-Out Tee Cap
Attaches 3” pipe to branch and 4” pipe to body. Use for a 90° offset. Branch swivels for alignment. Removable twist-lock clean-out tee cap included.
-
Adapter Tee w/ Clean-Out Tee Cap
Use for a 90° offset. Attaches directly to appliance as an adapter. Removable twist-lock Clean-Out Tee Cap.
-
Increaser Adapter Tee w/ Clean-Out Tee Cap
Use for a 90° offset. Attaches directly to appliance as an adapter. Converts a 3” appliance to a 4” Secure Pellet system. Removable twist-lock Clean-Out Tee Cap.
-
Double Tee w/ Clean-Out Tee Cap
Allows clean-out access for horizontal and vertical installations. Use for a 90° offset. Branch swivels for alignment. Removable twist-lock Clean-Out Tee Cap.
-
Wall Thimble
Use for through-the-wall installations. Fits between standard wall studs. Comes with an insulation ring to reduce air infiltration where the pipe slips through the thimble.
-
Wall Thimble Air Intake Kit
Allows outside fresh air for combustion through the wall thimble without having to cut a second hole into the wall. Comes with an insulation ring to reduce air infiltration where the pipe slips through the thimble. The 2” diameter, 18” length flex hose expands to 5’. Clamps included. Can be used in US and Canada. Patented.
-
Ceiling Support Firestop Spacer
Required where vent passes through ceiling. Centers pipe to provide proper 1” clearance. Support Clamp included. Painted black.
-
Ceiling Support Firestop Spacer - 3
Required where vent passes through ceiling. Centers pipe to provide 3” clearance. Support Clamp included. Painted black.
-
Wall Strap
Use to support vent pipe or tee sections. Provides 1” clearance.
-
Adjustable Wall Strap
Use to support vent pipe or tee sections. Adjusts to provide 1”- 3” clearance.
-
Wall Strap Extension
Use with Adjustable Wall Strap to increase extension from wall. Fits both 3” and 4” Adjustable Wall Strap.
-
Cathedral Ceiling Support Box
Use to support pipe. May be used on flat ceilings. Painted black. Trim and clamp included.
-
Ceiling Support/Wall Thimble Cover
Decorative cover for ceiling support boxes and wall thimbles. Painted black. Use with reduction collar.
-
House Shield
Use to protect exterior of structure from blower discharge in horizontal venting applications.
-
Attic Insulation Shield
Required for installations that pass through an attic to prevent insulation and debris from accumulating near the vent. Provides 1” clearance to combustibles.
-
Adjustable Roof Flashing
Use to weather proof the penetration of vent pipe through the roof. Storm Collar required. Select roof flashing based on pitch of roof. For pitches of 0/12 - 6/12.
-
Reduction Collar
Reduces the center hole diameter in the Ceiling Support /Wall Thimble Cover to fit 3” or 4” pipe. Can be used as trim collar when penetrating a masonry chimney with Secure Pellet. Painted black.
-
Tall Cone Roof Flashing
Use to weather proof the penetration of vent pipe through the roof. Storm Collar required. Select roof flashing based on pitch of roof. Use on flat roofs, chase enclosures, or masonry chimney. Made of galvalume.
-
Storm Collar
Use to maintain a weather tight resistant seal between the pipe and the flashing.
-
Vertical Cap
Use for vertical installations only. Required where pipe terminates above the roof line.
-
Horizontal Cap
Use for horizontal terminations only. The Horizontal Cap can be turned at the gore to direct exhaust output. Designed to create a venturi effect to force exhaust out. Made of a laser-welded, super-ferritic stainless steel inner wall that is scientifically proven to resist corrosion from corn and other biofuels. Outer wall made of laser-welded stainless steel.
-
Square Horizontal Cap
Use for horizontal terminations only. Cap features swivel collar to adjust exhaust direction. Cap features an optional swivel base.
-
Secure Pellet Flex
Use when relining masonry chimney for use with pellet appliances. Made of super-ferritic stainless steel. Must be used with Secure Pellet Male and Female Flex Adapters. Rigid pipe must be used when terminating system.
-
Prairie Termination Cap
Use when installing a pellet insert into a multi-fuel pellet stove. This termination cap supplies both fresh air and vents exhaust. Lid pivots open for cleaning with three Removable screws and one rivet. Flex sold separately.
304SS and 316SS flex can be used when burning most fuels. If burning corn, super-ferritic stainless steel Secure Pellet Flex must be used as the exhaust vent. For fresh air, aluminum flex can be used. Stainless steel flex is not required for the fresh air supply unless specified by the appliance manufacturer.
-
Fresh Air Inlet Increaser
Use to increase an insert’s 2” air inlet to connect to 3” aluminum flex.