Secure Temp ASHT+ for Canada
Finishing Cone
Black Pipe Adaptor
Decorative Collar Single-Wall
Decorative Trim
Spark Arrester Band
Rain Cap
Snow Diverter
Storm Collar
Adjustable Roof Flashing
Peak Roof Flashing
Flat Roof Flashing
Guy Wire Band
Universal Roof Brace
Universal Wall Band
Firestop
Angled Firestop 30º & 45º
30º & 45º Insulated Wall Radiation Shield
Insulated Wall Thimble
Insulated Radiation Shield
Adjustable Insulated Attic Radiation Shield
Two-Piece Insulated Attic Radiation Shield
Radiation Shield
Radiation Shield Connector Support
Radiation Shield Connector Firestop
Radiation Shield Connector (Insulated)
Flexible Shield
Telescopic Rigid Shield
Swivel Adaptor
Flue Extension
Anchor Plate
Floor Support
Universal Roof Support
Universal Offset/Wall Support
Adjustable Wall Support
Adjustable Tee Support
Tee Support
Adjustable Square Support, Black with Framing Arms and Coupler
Square Cathedral Support Extension
Square Cathedral Support with Coupler
Round Cathedral Support with Coupler
Finishing Support with Coupler
Drain Tee Cap
Insulated Tee Cap (Twist-Lock)
Insulated Tee
Double Base Tee
Base Tee
45º Insulated Elbow
30º Insulated Elbow
15º Insulated Elbow
Adjustable Lengths
Insulated Lengths
-
Finishing Cone
When the chimney passes through an exterior wall, a finishing cone may be used to conceal the protrusion of the insulated length (5") inside the dwelling. A flue extension must be used to ensure a perfect connection between the chimney and the double-wall black connector. -
Black Pipe Adaptor
This component is recommended for connecting a standard black pipe to the Secure Temp S2100+ chimney when a longer extension length is required. A finishing collar is supplied. -
Decorative Collar Single-Wall
This component provides a finish between the Secure Temp S2100+ chimney’s female coupler and single-wall stove pipe. Note: For double-wall stove pipe connection, see our “DL“ catalog section. -
Decorative Trim
The use of this decorative trim provides a flawless finish when a chimney must pass through a ceiling or any wall. -
Spark Arrester Band
This spark arrester band is wrapped around the rain cap, preventing sparks from falling onto the roof or animals from entering into the chimney. -
Rain Cap
Attached to the top of the chimney, it effectively prevents rain, snow and leaves from entering the opening. Check local codes to determine if a spark arrester (PE) is required. -
Snow Diverter
Three times thicker and stronger, allowing it to stand up against heavier snow loads. Bendable attachment flanges allow it to mount on any roof slope. Use to divert snow around chimney, vent and roof flashing. Constructed of paintable galvanized material. Ships flat for easy assembly. -
Storm Collar
Designed to fit over flashings, it provides a weather-tight seal. It is automatically supplied with roof flashings. -
Adjustable Roof Flashing
This part is required to accommodate sloped roof installations. Available in five versions to adapt to the needs of the following roof slopes: • 1/12 to 7/12 pitch: FA/XFA • 8/12 to 12/12 pitch: FB/XFB • 12/12 to 21/12 pitch: FBB/XFBB Also available in aluminum malleable base plate (Ref. FAA, FBA) -
Peak Roof Flashing
This component is required for chimney installations passing through the roof peak. It is available in two models: • Peak roof: 1/12 to 7/12 FP/XFP • Peak roof: 8/12 to 12/12 FPB/XFPB -
Flat Roof Flashing
This component seals a chimney length when passing through a flat roof and comes complete with a storm collar. -
Guy Wire Band
Attached to the outer casing of the chimney (secured by bolts), it is designed to hold 3 guy wires. It is recommended for chimneys exceeding the roof by 5’ to 13’ maximum. Wire not included. -
Universal Roof Brace
Designed to stabilize a chimney extending from 60" to 115" beyond the roof, or when a chimney is exposed to high winds. This part is supplied with tightening collar and adjustable legs. -
Universal Wall Band
Designed for use on an interior or exterior wall, it serves to stabilize the chimney while providing the required clearance from the combustible surface. The use of wall bands at maximum intervals of 8’ is recommended. Also available in 6" fix configuration (6BM) -
Firestop
Designed for use below each combustible floor the chimney passes through. -
Angled Firestop 30º & 45º
This angled firestop is to be used only with the Security wood-burning fireplace line and others that have been certified for use with the chimney. -
30º & 45º Insulated Wall Radiation Shield
Designed to protect surrounding combustible materials when a chimney crosses through a wall horizontally, this shield can be adjusted from 7" to 12-1/2" to adapt to the thickness of the wall opening. A decorative plate painted in matte black provides an interior finish. Insulated to prevent cold air intrusion. -
Insulated Wall Thimble
Designed to protect surrounding combustible materials when a chimney crosses through a wall horizontally, this shield can be adjusted from 7" to 12-1/2" to adapt to the thickness of the wall opening. A decorative plate painted in matte black provides an interior finish. Insulated to prevent cold air intrusion. -
Insulated Radiation Shield
Designed for use with wood-burning stoves or fireplaces certified for use with the SecureTemp ASHT+ or S2100+ chimneys, it should be used where the chimney passes through a ceiling or exterior opening where insulation is required. It must be used in combination with an attic radiation shield when passing through an attic. Recommended for use in cold regions. -
Adjustable Insulated Attic Radiation Shield
Also referred to as an insulation shield, this has the same features as the two-piece insulated attic radiation shield but its height is adjustable from 12" to 22". Insulated to prevent cold air intrusion. Storm collar included. -
Two-Piece Insulated Attic Radiation Shield
Also referred to as an insulation shield, it protects combustible materials when a chimney passes through an attic. It is imperative that it be installed overside from the attic. Its cone shape keeps insulation from seeping between the outer casing and the firestop. It also maintains a 2" clearance from combustible materials. Insulated to prevent cold air intrusion. Storm collar included. -
Radiation Shield
Protects combustible materials when the chimney passes through a floor or an intermediate ceiling. It ensures a 2" safety clearance between the chimney’s outer casing and surrounding combustibles. When passing through a ceiling, it must be installed from the underside of the ceiling. (Required in some jurisdictions in replacement of the firestop.) -
Radiation Shield Connector Support
Used in conjunction with a radiation shield connector (SRS) on floors where the chimney needs to be supported (for example, after an offset). -
Radiation Shield Connector Firestop
-
Radiation Shield Connector (Insulated)
Used in conjunction with a radiation shield connector support (RSSR) or firestop (RCSP) where the enclosed chimney passes through a ceiling/floor. It attaches to the chimney using 4 screws through brackets. A storm collar must be used at the top in an attic installation. -
Flexible Shield
Designed for use in the same applications as a rigid shield where an offset is required. -
Telescopic Rigid Shield
Used as a casing shield around the chimney only where it is enclosed inside a building (for example, between floors or in a chase). It attaches with screws to a radiation shield connector at each floor/ceiling. -
Swivel Adaptor
Designed for use as an option to ease the connection in tight spaces between the flexible shield and the radiation shield connector (SRS) -
Flue Extension
Fitted to the base of the first chimney length, this component makes it possible to extend the inner casing, thereby facilitating the attachment of the stove pipe or other type of connector. It can also be attached directly to the appliance outlet as a chimney adapter. The crimped end of this component is slightly tapered for easier assembly. -
Anchor Plate
This part is attached to a masonry or metal-casing fireplace to provide a proper connection to the chimney. It can also serve to connect a furnace. (Refer to the chart on pg. 4 or 8 for loadbearing capacity.) -
Floor Support
Used mainly from a basement, this part supports the chimney on a slab, floor, or joist and also acts as a firestop. It makes it possible to maintain a 2" clearance between the chimney’s outer casing and combustible materials in its path. It includes a tightening collar that locks around the chimney and is secure by self-tapping screws (included). The collar rests on a horizontal plate screwed or nailed to the floor or slab. It can also serve as an intermediate support. (Refer to the chart on pg. 4 or 8 for load-bearing capacity.) -
Universal Roof Support
This complementary support is usually attached to a roof structure. It is designed to support the chimney: • from the roof, adjusting to any roof pitch • above an offset • when the chimney height exceeds the loadbearing capacity of the primary support. Two adjustable plates screwed to the structure adapt to the pitch of the roof. A tightening collar is attached and locks around the chimney. It is secured by self-tapping screws. (Refer to the chart on pg. 4 or 8 for loadbearing capacity.) -
Universal Offset/Wall Support
This part is designed to support the chimney on a vertical wall. The triangular plates allow a 2" to 4" lateral adjustment of the support to the vertical surface. This support can also be used as a wall support above the insulated tee. When used as a tee support, it lends itself to the addition of a Twist-Lock insulated tee cap (TI or XTCI). (Refer to the chart on pg. 4 or 8 for loadbearing capacity.) -
Adjustable Wall Support
This part supports the chimney at the base of the installation or along a wall or other vertical surface serving as an intermediate support. It comes with a tightening collar that locks around the chimney and is secured by two self-tapping screws (included). The collar rests on a horizontal plate. When used as a base support, it lends itself to the addition of a Twist-Lock insulated tee cap (TI or XTCI). (Refer to the chart on pg. 4 or 8 for loadbearing capacity.) -
Adjustable Tee Support
This part supports the chimney at the base of the installation, functioning similarly to the tee support (SM) but with an adjustable base to provide additional wall clearance as needed. This tee support must be installed with the insulated tee cap (TCS) included with the insulated tee. -
Tee Support
This part supports the chimney at the base of the installation. It is designed with a male coupler to accommodate the first section of the chimney. This tee support is made of galvanized steel and must be installed with the insulated tee cap (TCS) included with the insulated tee. -
Adjustable Square Support, Black with Framing Arms and Coupler
This part has the same use as the SFC or SSC, but has adjustable arms that extend to reach framing for support. It can be installed between 16"- on center joists with 2-1/2" of free play to eliminate the need for elbows. No framing is required. -
Square Cathedral Support Extension
This part is designed to extend the finish of the cathedral support when the pitch of the roof is quite steep. It must be attached to the square cathedral support.It fits all diameters of the square cathedral support (XSSC). -
Square Cathedral Support with Coupler
This part is used to support a chimney that is passing through an angled ceiling. Fits between standard 16"- on-center joists. Designed to connect to both double-wall and single-wall stove pipe. An adjustable black finish trim is included. (Refer to chart on pg. 4 or 8 for loadbearing capacity.) -
Round Cathedral Support with Coupler
This part supports the chimney from a cathedral ceiling. Designed to connect the black stove pipe, it comes in a decorative black matte finish and must be attached to a frame built from the joists. (Refer to chart on pg. 4 or 8 for loadbearing capacity.) -
Finishing Support with Coupler
This part supports the chimney from a ceiling. Designed to connect to both double-wall and single-wall stove pipe, it is enhanced by a decorative black finish. Fits between standard 16"- on-center joists. Must be attached to a frame built from the joists. (Refer to chart on pg. 4 or 8 for loadbearing capacity and size of openings.) A finishing support is also available with a removable collar for 5" (5SFCA and 6" (6SFCA) installations. -
Drain Tee Cap
Fitted at the base of an insulated tee, it makes it possible to collect and drain rainwater and condensates. The drain tee cap connects to a drain (NPT 0 1"). Removable, it provides easy access for chimney maintenance or inspection. Must be combined with an adjustable wall support only. -
Insulated Tee Cap (Twist-Lock)
Equipped with a Twist-Lock system, it makes it possible to seal the base of an insulated tee when an adjustable wall support (SME or XSME) is used. It can be removed, providing easy access for chimney maintenance and inspection. Its insulation prevents the cooling of chimney gases, especially in exterior installations. -
Insulated Tee
Located at the base of the chimney, it provides the horizontal connection to the appliance. It is recommended for installations where a connector must pass through an exterior wall because its insulation prevents the cooling of chimney gases. An insulated tee cap (TCS) is included, which allows easy access for maintenance and inspection. The insulated tee cap (TCS) must be secured to the flue extension of the tee support or adjustable tee support. -
Double Base Tee
This component makes it possible to connect two appliances, such as a furnace and a water heater to the SecureTemp™ ASHT+ chimney. The galvanized steel base tee for twin connections comes with a tee cap (TC) to provide access for inspection and cleaning. -
Base Tee
Located at the base of the chimney, it makes it possible to connect the chimney to a gas- or oil-burning appliance. It is recommended for interior installations only and must be attached to a flue extension. The galvanized steel base tee comes complete with a tee cap to provide access for inspection and cleaning. Available in stainless (TBS). -
45º Insulated Elbow
Allows the 45° offset of a chimney. Designed to bypass an obstacle, such as a joist. A maximum of two offsets (4 elbows) is allowed. The chimney’s angle of inclination must not deviate more than 45° from the vertical position. -
30º Insulated Elbow
Allows the 30° offset of a chimney. Designed to bypass an obstacle, such as a joist. A maximum of two offsets (4 elbows) is allowed. -
15º Insulated Elbow
Allows the 15° offset of a chimney. Designed to bypass an obstacle, such as a joist. A maximum of two offsets (4 elbows) is allowed. -
Adjustable Lengths
Used in combination with straight insulated lengths, the adjustable length makes it possible to fit a Secure Temp length perfectly. IMPORTANT: The adjustable length is not designed as a loadbearing component. Its vertical installation requires an appropriate support on the section above it to bear the weight of the remaining installation. -
Insulated Lengths
ASHT+: Five diameters and six standard effective lengths featuring a 1/8-turn Twist-Lock assembly. S2100+: Three diameters and six standard effective lengths featuring a 1/8-turn Twist-Lock assembly. Various lengths may be combined to obtain the required installation height.